![background image](http://html2.mh-extra.com/html/paradox/digiplex-dgp-620/digiplex-dgp-620_installers-manual_3620540015.webp)
Digiplex LED Keypads 13
4.4 C
ONFIDENTIAL
M
ODE
Section 002: Option [4] and [5]
In Confidential Mode all LEDs will extinguish until either a button
is pressed or an access code is entered. Confidential
Mode is
activated by enabling option
[4]
. Option
[5]
regulates whether the
keypad will be activated at the touch of a button or only when an
access code is entered.
Once the keypad is activated,
Normal Mode
will appear and
all
applicable LEDs will illuminate:
• The “AC” Light if power is present
• The Numerical Symbols representing any open zones
• The Area Symbols if any areas are armed
• The
[
MEM
]
Symbol if any alarms have occurred
• The
[
TRBL
]
Symbol if any troubles are occurring
• The
[
BYP
]
Symbol if zones are bypassed
and show the status of the “Status” Light
Option
[4]
OFF= Normal Mode (default)
Option
[4]
ON = Confidential Mode
Option
[5]
OFF= LEDs activated by entering an access code (default).
Option
[5]
ON = LEDs activated by pressing a button.
Note: Option
[4]
must be set to OFF on UL Listed Systems.