![background image](http://html2.mh-extra.com/html/paradox/digiplex-dgp-620/digiplex-dgp-620_installers-manual_3620540020.webp)
18 Installer’s Manual
1) In section
[007]
, enter the first digit where each digit from 8 to
F represents an event group (0 = PGM Disabled).
2) Then enter the second digit, which can be any digit from 0 to F
depending on the first digit chosen.
3) After entering the second digit, use
Feature Select Programming
to enable/disable options
[1]
to
[8]
. Select up to eight specific
events as detailed in the
PGM Programming Table
.
These buttons represent the hexadecimal values from A to F:
5.3 PGM D
EACTIVATION
E
VENT
Section 008
Once the
PGM Activation Event
(see section 5.2 of this manual)
has occurred, the keypad's on-board PGM will return to its
[
STAY
]
= A (
[
STAY
]
will illuminate)
[
DISARM
]
= D (
[A4]
will illuminate)
[
FORCE
]
= B (
[
FORCE
]
will illuminate)
[
BYP
]
= E (
[
BYP
]
will illuminate)
[
ARM
]
= C (
[A1]
will illuminate)
[
MEM
]
= F (
[
MEM
]
will illuminate)