6.2.2.1 Direct output control
Table. 6.2.2.1 - 368. Generator commander output signals.
Output signal name
Description
GMAG Field current limiter
active
The delayed field current limiter is running.
GMAG Under excitation
limiter active
The underexcitation limiter is running.
GMAG Stator current limiter
overexcited active
The stator current limiter is running (overexcited).
GMAG Stator current limiter
underexcited active
The stator current limiter is running (underexcited).
GMAG High active current
The high active current exceeds the stator current limiter threshold.
GMAG Instantaneous field
current limiter
The instantaneous field current limiter is running.
GMAG Low supply voltage
Low supply voltage.
GMAG FCR mode
The FCR mode is selected.
GMAG AVR mode
The AVR mode is selected.
GMAG MVAR mode
The MVAR mode is selected.
GMAG PF mode
The PF mode is selected.
GMAG Low measured
voltage
Low measured voltage.
GMAG IGBT shorted
The IGBT output has shorted out.
GMAG PWM enable
The bridge is in the Run mode.
GMAG PWM AC1 ON
When using at least two bridges, Bridge 1's AC supply MCB is not tripped and the supply
voltage is OK. Therefore, the AC supply is selected.
GMAG PWM DC1 ON
When using at least two bridges, the AC supply MCBs of both Bridge 1 and Bridge
2 are tripped and the supply voltage is not OK. Therefore, the DC supply is selected.
GMAG PWM AC2 ON
When using at least two bridges, Bridge 2's AC supply MCB is not tripped and the supply
voltage is OK. Therefore, the AC supply is selected.
GMAG PWM DC2 ON
When using at two bridges, the AC supply MCBs of both Bridge 1 and Bridge 2 are tripped and
the supply voltage is not OK. Therefore, the DC supply is selected.
GMAG Rectifier trip
The rectifier is tripped through an excitation common trip.
GMAG Bridge 1
temperature high
Trip caused by a high temperature from Bridge 1.
GMAG Bridge 2
temperature high
Trip caused by a high temperature from Bridge 2.
GMAG Excitation ON
Excitation is running.
GMAG Excitation OFF
Excitation is not running.
GMAG Overcurrent
Trip caused by an excitation overcurrent.
GMAG Bridge 1 DI1 signal
Digital input statuses from AQ-GC30 rectifier units.
The possible values are:
1: Single or reduntant Channel 1
2: Reduntant Channel 2
GMAG Bridge 1 DI2 signal
GMAG Bridge 1 DI3 signal
GMAG Bridge 1 DI4 signal
GMAG Bridge 1 DI5 signal
GMAG Bridge 1 DI6 signal
Genera
Generattor Commander
or Commander
Instruction manual
Version: 2.07
446
© Arcteq Relays Ltd
IM00001
Summary of Contents for Generator Commander
Page 1: ...Generator Commander Instruction manual...
Page 2: ......