If the circuit is open, shorted to negative: carry out the check procedure on the component
and the EVC connector. Disconnect the two connectors and check for continuity of the cable
between potentiometer PIN 2 and EVC PIN A5 and restore the cable harness. If the cable
harness is intact check component PIN 2 ground insulation: if insulation is not present, re-
store the cable harness; otherwise replace the component.
(Caponord 1200 Travel Pack)
DIAGNOSTICS INSTRUMENT: LOGIC ERRORS
Exhaust butterfly valve position P0190
•
position error.
Error cause
•
Position indicated by potentiometer does not correspond with position set by control unit.
Troubleshooting
•
Mechanically check the valve, its normal rotation (with cables disconnected from motor,
manually activate the cables and see movement regularity and check valve complete stroke
with correct operation of the return spring) and absence of foreign bodies which do not allow
its rotation: if not OK, restore; if OK, check valve and instrument panel connectors (special
attention to oxidation) and check cables resistance: if not OK, restore; if OK, always with
cables disconnected and key set to ON, check normal rotation of the electric motor and
replace motor (potentiometer does not work correctly).
DIAGNOSTICS INSTRUMENT: ADJUSTABLE PARAMETERS
•
Acquire exhaust butterfly valve zero position.
NOTE: Motor is placed in a reference position to correctly search mechanical stop later.
•
Exhaust butterfly valve self-acquisition
NOTE: Search minimum and maximum mechanical stop.
Exhaust butterfly valve stop search P0191
•
excessive time / search not carried out, incorrect travel / potentiometer signal above MAX
threshold and under MIN threshold
Error cause
•
If search not carried out. Carry out travel stop search.
•
If time is excessive: failure to memorise valve stop positions. The VCU is unable to record
the valve stops: probable circuit interruption. If the search is not carried out, incorrect travel:
memorisation of valve stop positions absent: this occurs at the first start of the bike or fol-
lowing a control unit reset.
•
If incorrect travel, carry out reset, cable adjustment and stop search again.
Troubleshooting
Electrical system
Caponord 1200 - Caponord 1200 Rally
ELE SYS - 232
Summary of Contents for Caponord 1200 2016
Page 1: ...MANUALE STAZIONE DI SERVIZIO 2Q000020 Caponord 1200 Caponord 1200 Rally ...
Page 6: ......
Page 7: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 66: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Page 73: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 85: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Page 90: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 134: ...key 1 MULTIPLE CONNECTORS Electrical system Caponord 1200 Caponord 1200 Rally ELE SYS 134 ...
Page 138: ...key 1 MULTIPLE CONNECTORS Electrical system Caponord 1200 Caponord 1200 Rally ELE SYS 138 ...
Page 268: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 284: ...INDEX OF TOPICS ENGINE ENG ...
Page 371: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Page 374: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 417: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 451: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 480: ...INDEX OF TOPICS CLUTCH SYSTEM CLU SYS ...
Page 483: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 492: ...INDEX OF TOPICS BODYWORK BODYW ...
Page 549: ... Remove the inside fairing Caponord 1200 Caponord 1200 Rally Bodywork BODYW 549 ...
Page 550: ...INDEX OF TOPICS ...
Page 551: ...PRE DELIVERY PRE DE ...
Page 573: ...Tyres 17 U Use 460 W Warning lights Water pump 488 Wiring diagram 133 ...