CNC Setup Utility Manual
P/N 70000490C - Tuning the Current, Velocity, and Position Controller
5-16
All rights reserved. Subject to change without notice.
10-December-04
The MST screen displays:
I/O Monitor>
X30: 0
3-D Probe: 0
Manual Panel
T Probe: 0
IN: 0123456789 0123456789 0123456789 01
Module 0
IN: 0123456789 0123456789 0123456789 01
OUT: 0123456789 0123456789 0123
Any active high (1) input or output will be displayed with its number
highlighted and vice versa.
X30
Displays the state of the spindle reference input.
Spindle proximity switch is connected to X30. This
determined by the definition set for
MC_5020
(Logic of
device used for X30 input).
Values: [0 (open) or 1 (closed) when
MC_5020
is Normal
closed and vice versa when Normal open]
3-D Probe
Displays the state of the trigger signals (deflected or not) in
the X12 connector. Connector X12 corresponds to the 3-D
Probe.
Values: [0 (probe deflected) or 1 (not deflected)]
T Probe
Displays the state of the trigger signals (deflected or not) in
the X13 connector. Connector X13 corresponds to the
Touch Probe.
Values: [0 (probe deflected) or 1 (not deflected)]
This test may be activated at the same time that the Index Pulse test
IndexP
(
F3
). This provides the marker pulse of the spindle motor and
displays the state of the spindle proximity switch (X30). In order to have
both tests active, the Index Pulse test must be activated first.