CNC Setup Utility Manual
P/N 70000490C - Machine Constants
All rights reserved. Subject to change without notice.
10-December-04
2-25
Table 2-2, Machine Constants Setup
(Continued)
Machine Constant
Parameter
Function Settings
MC_2134:
Y Torque LP Filter
Timecons (.1ms)
Y-axis torque lowpass filter time
constant is used when there is
insufficient dumping of the axis.
Standard value is zero.
Realistic input values 3–20 (0.1msec)
Range (0.00–10000.00)
0.00 (0.1ms) [Default]
MC_2135:
Y Torque Notch Filter
Freq. (.1Hz)
Vibrations can occur on critical axes
and at the spindle in a frequency range,
which cannot be compensated either
with the differential factor (MC_2125) or
with the MC_2134.
Range (0.00–10000.00)
0.00 (0.1Hz) [Default]
MC_2136:
Y Torque Notch Filter
Damp. (.1dB)
Y-axis damping values of the torque
band-stop filter.
Damping should not be set
unnecessarily high which would restrict
the operation of the control loop.
Realistic input values are 30–90
(0.1dB).
Range (0.00–10000.00)
0.00 (0.1dB) [Default]
MC_2150: Y Display
Resolution
.5 Micron
1
Micron
[Default]
2 Micron
5 Micron
10 Micron
MC_2151:
Y In-position
Tolerance Range
Range (0.0000–9.0000)
0.0004 (inch) [Default]
MC_2152:
Y Default Feed Rate
Setting the Y-axis Default Feed Rate
establishes a default feedrate for the Y-
axis, wherever a feedrate has not been
programmed. This applies to
programmed blocks or MDI commands.
Jog moves in feed (that is, from a
manual panel) can have a different
feedrate.
Range (1.–50800.)
10. (inch/min) [Default]
MC_2153:
Y Default Rapid Rate
Range (1.–50800.)
500. (inch/min) [Default]
(Continued…)