Table 2-2, Machine Constants Setup
(Continued)
Machine Constant
Parameter
Function Settings
Z-axis Setup Parameters
MC_2200:
Z Motor Encoder
Connector
The connection to which the motor
encoder for the Z-axis is connected.
X15
X16
X17
[Default]
X18
X19
MC_2201:
Z PWM Output
Connector
Defines the Z-axis PWM output drive.
X55
X51
X52
X53
[Default]
X54
MC_2202:
Z Inverter Type
The inverter type identifies the Z-axis
inverter being used. Inputting the wrong
inverter type can result in undesired
axis behavior or inverter damage.
COMPACT
[Default]
PM 107
PM 115A
PM 123A
PM 132A
PM 148A
PM 207
PM 215A
PM 223A
MC_2203:
Z Motor Type
The Z-axis motor type is identified by
the motor name. Inputting the wrong
motor number can result in undesired
axis behavior or motor damage.
AM 1400AB
[Default]
(See MC_2003 for a complete
setting list)
MC_2204:
Z Linear Encoder
Connector
Selects the measuring system input for
the Z-axis linear encoder.
NONE
(none) [Default]
X1
X2
X3
X4
X6
(Continued…)