FAULT
6
TROUBLESHOOTING
Fault
Causes
Remedies
Smell of gas.
Occasional leak because flame
has gone out.
Turn off the gas supply tap and
ventilate the room.
The flame is yellow.
Burner dirty, heat exchange pipes
clogged, condensation drips.
Contact the after-sales
service.
.
The appliance does
not heat up.
Check the thermostat and activate
any start-up enabling device.
Contactor not receiving power or
faulty.
Check or replace the contactor
coil.
The control panel does not
come on
Electronic circuit board not
receiving electrical power.
Check or swap the phase wire
connections.