background image

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS  010706

Product Dimensions

Super Capacity Washing Machines
W1203, W1213, W1215 SS

2"

23 1/2"

33 3/8" - 34 1/8"

26 1/2"

3 3/4" - 4 1/2"

D -

E -

W -

5 foot flexible drain hose connects
upper left rear.
208-240 Volt - 15 Amp 5 foot 4-wire
(2 live / neutral / ground) molded plug
power supply connects upper right
rear (NEMA 14-30 Configuration).
5 foot separate flexible hot and cold
water intake hoses connect upper left
rear.

Location Codes

25 1/2"

Notes

• All installations must be done in accordance with local codes
• See "Cut-out Dimensions" sheet for undercounter or built-in space requirements
• Optional Easy Installation Kits utilize existing 208-240 Volt - 30 Amp line to

connect two Miele machines without rewiring.

• Remove transport struts in rear of machine before installation.

D

W

E

Summary of Contents for Touchtronic T 1403

Page 1: ...ower supply connects upper right rear NEMA 14 30 Configuration 5 foot separate flexible hot and cold water intake hoses connect upper left rear Location Codes 25 1 2 Notes All installations must be done in accordance with local codes See Cut out Dimensions sheet for undercounter or built in space requirements Optional Easy Installation Kits utilize existing 208 240 Volt 30 Amp line to connect two ...

Page 2: ...pacity Laundry Products 24 28 min Water Electrical Connection Location C 32 3 8 35 1 4 Typically requires removal of unit s lid Out of box unit height dimension without lid is 32 5 16 32 11 16 Notes Location Codes C Cutout for Water Drain and Electric pass through Adjust according to water and drain location ...

Page 3: ...xisting 208 240 Volt 30 Amp Product Dimensions Easy Installation Kits 057B 060B Notes Connect Washer and Dryer to Easy Installation Kit All installations must be done in accordnace with local codes 057B Kit fitted with a NEMA10 30 Plug 060B Kit fitted with a NEMA14 30 Plug ...

Page 4: ...e SPECIFICATION SHEETS 010706 Product Dimensions Laundry Stand WTS420 White Only 26 11 Notes For use with both large and super capacity washers or tumble dryers All installations must be done in accordnace with local codes 23 3 8 ...

Page 5: ...ug power supply connects upper right rear NEMA 14 30 configuration 5 foot separate flexible hot and cold water intake hoses connect upper left rear Location Codes Notes All installations must be done in accordance with local codes See Cut out Dimensions sheet for undercounter or built in space requirements Optional Easy Installation Kits utilize existing 208 240 Volt 30 Amp line to connect two Mie...

Reviews: