- Risk of Fire
• Clothes dryer installation must be performed by a
qualified installer.
• Install the clothes dryer according to these instructions
and local codes.
•
DO NOT
install a clothes dryer with flexible plastic venting
materials. If flexible metal (semi-rigid or foil-type) duct is
installed, it must be UL-listed and installed in accordance
with the instructions found in “Connecting the Dryer
to House Vent” later in this manual. Flexible venting
materials are known to collapse, be easily crushed and
trap lint. These conditions will obstruct dryer airflow and
increase the risk of fire.
•
DO NOT
install or store this appliance in any location
where it could be exposed to water or weather.
• To reduce the risk of severe injury or death, follow all
installation instructions.
• Save these instructions. (Installers: Be sure to leave
these instructions with the customer.)
In the Commonwealth of Massachusetts,
the following installation instructions apply:
• Installation must be performed by a qualified or
licensed contractor, plumber, or gasfitter qualified
or licensed by the State.
• If using a ball valve, it shall be a T-handle type.
• A flexible gas connector, when used, must not
exceed 4 feet.
FOR GAS DRYERS ONLY
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT
–
Save these instructions for local electrical
inspector’s use.
IMPORTANT
–
Observe all governing codes and
ordinances.
• Install the clothes dryer according to the manufacturer’s
instructions and local codes.
• Note to Installer –
Be sure to leave these instructions
with the Consumer.
• Note to Consumer –
Keep these instructions for future
reference.
• Clothes dryer installation must be performed by a qualified
installer.
• This dryer
must
be exhausted to the outdoors.
• Before the old dryer is removed from service or discarded,
remove the dryer door.
• Do not allow children on or in the appliance. Close
supervision of children is necessary when the appliance
is used near children.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
• Install the dryer where the temperature is above 50°F for
satisfactory operation of the dryer control system.
• Remove and discard existing plastic or metal foil duct
and replace with UL-listed duct.
• Service information and the wiring diagram are located
in the control console.
08-22 GEA
31-3000199
Rev 1
Questions? Call GE Appliances at 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com
Dryers
Installation
Instructions
WARNING