IT
GB
DE
FR
ES
- 24 -
C13222
420_1.
fm
English
Important
Make the connection in compliance with
the relevant legal requirements, using ap-
propriate and recommended materials.
Connecting to a fan extractor hood
To carry out this operation, proceed as follows.
1 - Position the appliance underneath the hood
(A)
(see diagram).
Important
The gas supply tap must open automatical-
ly when the fan of the extraction system is
switched on.
CONNECTION OF FUME EXHAUST VENT
Important
The connection must be made by authori-
sed, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials.
The appliance is supplied with operating
voltage 230V/1N 50Hz (220V/1N 60Hz availa-
ble on request).
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A)
with overload cutout and differential safety
breaker close to the appliance.
2 - Undo the screws
(B)
to remove the guard
(C)
.
3 - Undo the screws
(D)
to remove the lid
(E)
.
4 - Fit the power supply cable into the cable gland
(F)
.
5 - Connect the circuit-breaker
(A)
to the terminal
board
(G)
of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
Use a flexible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
ture of at least 80°C.
Important
When connecting, take care to connect the
neutral and earth lines.
ELECTRICAL CONNECTION