background image

Record the Serial number and Model number of this Instant Recovery

®

 

Gas Fryer in 

the spaces provided. 

Keep these numbers for future reference.

INSTANT RECOVERY

®

 

GAS FRYER

SERIES 2009

KEEP A COPY OF YOUR BILL OF SALE. 

The date on the bill establishes the warranty period should service be required. 
If service is performed, it is in your interest to obtain and keep all receipts.

Keating commercial fryers are not intended for household use.

As continuous product improvement occurs, specifi cations may be 
changed without notice.

IMPORTANT:

THE USER'S MANUAL PROVIDES SPECIFIC OPERATING INSTRUCTIONS 
FOR YOUR MODEL. USE THE INSTANT RECOVERY® GAS FRYER ONLY AS 
INSTRUCTED IN THIS MANUAL.

Part # 038142

gasfryer2009_2013

11

/15

1-800-KEATING  |  keatingofchicago.com

MANUAL

KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL.

SERIAL NUMBER

MODEL NUMBER

Summary of Contents for 2009 Series

Page 1: ...formed it is in your interest to obtain and keep all receipts Keating commercial fryers are not intended for household use As continuous product improvement occurs specifications may be changed without notice IMPORTANT THE USER S MANUAL PROVIDES SPECIFIC OPERATING INSTRUCTIONS FOR YOUR MODEL USE THE INSTANT RECOVERY GAS FRYER ONLY AS INSTRUCTED IN THIS MANUAL Part 038142 gasfryer2009_2013 11 15 1 ...

Page 2: ...FACTURER S INSTRUCTIONS THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM THE EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE BASIC PLUMBING CODE OF THE BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL INC BOCA AND THE FOOD...

Page 3: ...ill assure top performance Alterations of any kind to your equipment will void the warranty Before uncrating check equipment carefully for damage IF EQUIPMENT ARRIVES DAMAGED Keating does not assume responsibility for loss or damage incurred in transit IMPORTANT This merchandise has been thoroughly inspected and carefully packed before leaving our plant Responsibility for its safe delivery was ass...

Page 4: ...S ODOR IS DE TECTED SHUT DOWN UNIT AT MAIN SHUT OFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR EMERGENCY SERVICE You must maintain this appliance free and clear from combustibles You must maintain the following minimum clearances from combustible and non combustible construction MINIMUM CLEARANCE CONSTRUCTION CLEARANCES COMBUSTIBLE NON COMBUSTIBLE BACK 6 0 RIGHT SIDE 6 0 LEFT SIDE...

Page 5: ...d the local installer to comply with national and local codes NATIONAL CODE REQUIREMENT The installation must conform with local codes or in the absence of local codes with the National Fuel Gas code ANSI Z223 1 or the Natural gas Installation Code CAN CGA B149 1 or the Propane Installation Code CAN CGA B149 2 Flexible connectors must comply to ANSI Z221 69 CAN CGA1 16 Keating equipment is designe...

Page 6: ...le Keating Gas Fryer requires a standard gas pipe size of 3 4 inch 19mm I D connection Multiple fryers with a common manifold will require a minimum of 1 1 4 inch I D gas supply line The size of the gas supply pipe is very important If the pipe is too small you will have low gas pressure at the Keating Gas Fryer manifold Low gas pressure will cause slow recovery and or delayed ignition amongst oth...

Page 7: ...ade for cooking THIS FRYER MAY NOT BE ALTERED MODIFIED OR CHANGED IN ANY WAY NOTE It is estimated that half of all service calls made on Keating Instant Recovery Fryers result from an inadequate gas supply During installation have a gas company representative make certain that the fryer is receiving adequate gas pressure and volume see In stallation or your serial plate on the fryer door PROPANE G...

Page 8: ...to the ON position The burners will come on SHUTDOWN PROCEDURE 1 Set thermostat to the OFF position 2 Turn MAIN POWER switch to the OFF position 3 Turn gas valve knob to the OFF position 4 Turn gas supply valve to the OFF position 5 Check to make sure all burners and pilot are extinguished SERIES 2000 BB MODELS OPERATING INSTRUCTIONS DO NOT START FRYER WITHOUT FIRST FILLING FRY POT START UP PROCED...

Page 9: ...rs will come on Select MELT with solid shortening until liquid shortening is 1 from full then switch to the FRY position after packing shortening around burner tubes SHUTDOWN PROCEDURE 1 Set thermostat to the OFF position 2 Turn MAIN POWER switch to the OFF position 3 Check to make sure all burners and pilot are extinguished SERIES 2000 TS MODELS OPERATING INSTRUCTIONS DO NOT START FRYER WITHOUT F...

Page 10: ...the OFF position Its green light will go off 3 Check to make sure all burners and pilot are extinguished SERIES 2009 TS SPARK IGNITION MODELS OPERATING INSTRUCTIONS DO NOT START FRYER WITHOUT FIRST FILLING FRY POT START UP PROCEDURE 1 Set thermostat to the OFF position 2 Turn MAIN POWER switch to the ON position Its green light and the timers will come on 3 Set thermostat to desired temperature 4 ...

Page 11: ... or relighting fryer SERIES 2000 CPU SPARK IGNITION MODELS OPERATING INSTRUCTIONS DO NOT START FRYER WITHOUT FIRST FILLING FRY POT START UP PROCEDURE 1 Turn gas supply to the ON position 2 Depress the MAIN POWER switch to the ON position 3 Turn CPU to the ON position 4 Select melt cycle or heat setting 5 Select the desired temperature See the computer manual for more information SHUTDOWN PROCEDURE...

Page 12: ...Repeat the process as necessary for the other timers OPERATING LOGIC When the timer is powered up the display will show the time setting for the cook time that was operated last and the relay output contacts will be open To start a cycle press the desired cook time button T1 T2 or T3 The display will begin to countdown from the preset time setting and the relay output contacts will close During th...

Page 13: ...illage 5 Close the drain valve 6 Fill fryer vessel to Max line with water 7 Set thermostat and turn fryer on to bring water to a gentle boil Once boil has been reached turn fryer off UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL OUT TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PREVENT BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEAT TRANSFER TUBES ...

Page 14: ...ring water to a gentle boil Once boil has been reached turn fryer off UNDER NO CIRCUMSTANCES SHOULD THE FRYER AND FILTER BE LEFT UNATTENDED DURING BOIL OUT TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PREVENT BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEATING TRANSFER TUBES 11 Dissolve 2 3 cup of Keating Sea Powder for every five gallons of water and let soak for 1 2 hour...

Page 15: ...our fryer working efficiently Proper care and servicing will lead to years of quality performance PREVENTATIVE MAINTENANCE CHART TIME FRAME OPERATOR OWNER AT LEAST DAILY Check lights and controls Check that the oil is up to Max line Clean all baskets Drain strain or filter oil AT LEAST WEEKLY Drain and clean fryer Boil out fryer AT LEAST BI MONTHLY Hi Limit Test procedures AT LEAST MONTHLY Check c...

Page 16: ...ill cycle rapidly while the fryer is in the idle mode the temperature will be erratic REQUIRED TEST THERMOSTAT Multimeter for testing continuity CHECKING CONTINUITY WITH THE MULTIMETER 1 Rotate the thermostat shaft until an audible click is heard 2 Rotate the thermostat shaft left and right ten times causing the switch to click on and off ten times while using the Multimeter to verify continuity 3...

Page 17: ...valve must be replaced BEFORE REPLACING THERMOPILE CHECK MILLIVOLT READINGS THERMOPILE READINGS With all wires connected with the pilot on and burners off the thermopile reading at the TP THTP terminals should be 325mv With the burners on the millivolt reading should be 200mv A replacement thermopile part is 022770 WARRANTY REPAIRS Keating s warranty begins with the date of installation In the eve...

Page 18: ... built in filter system a Turn manual gas valve on If using flexible connector with quick disconnect make sure quick disconnect is completely engaged b Plug fryer into approved outlet c Rotate gas valve knob to pilot position Depress and hold for 30 seconds d Push Hi Limit reset button located under control panel e Turn fryer and manual gas valve off Clean orifice s and other parts as necessary f ...

Page 19: ...your HVAC representative d Verify if size of incoming gas line to fryer and manifold gas pressure are adequate Oil in fryer vessel smokes a Oil has begin to breakdown b High carbon content in oil c Dirty fryer vessel d Inferior grade of oil e Fryer is overheating f Hi Limit Control has failed a Replace oil b Filter oil completely replace if necessary c Boil out fryer d Check with supplier for the ...

Page 20: ...aulty b Breaker has tripped c Basket lift relay is faulty d Actuator is defective a Tighten connections Replace timer if faulty b Reset breaker located on power box in rear of fryer Citcuit breakers on newer units can be found under the control panel c Replace relay d Replace actuator if 24VDC is present Fryer is making a lot of noise a Misadjusted air shutters on the burners a Loosen screw that h...

Page 21: ... 1 1 1 2 12 RUNNER PILOT SOLENOID ADAPTER ALL 005743 1 1 1 1 1 1 13 ALUMINUM 1 4 TUBING Specify length SERIES 2000 2005 1 800 KEATING 1 1 3 3 3 5 14 CORRUGATED 1 4 TUBING Specify length 1 800 KEATING 15 RADIANT TURBULATOR ALL 056125 2 3 4 4 6 16 BURNER ALL 028048 2 3 4 4 5 6 17 BURNER ORIFICE 1 800 KEATING 015204 2 3 4 4 5 6 18 BURNER HOLD DOWN BAR 1 800 KEATING 1 1 1 1 1 2 19 BURNER SPACER 18 AND...

Page 22: ... 4 26 13 8 7 6 10 MANIFOLD MANIFOLD PANEL 22 19 LEG CHANNEL WITH LEGS AND BULLET FEET DOOR SPLASHBACK 18 21 16 BURNER AIR SHUTTER 15 24 20 FLUE Top Side Views Front View Top Side Views Front View Door Catch Magnet Series 2000 to 11 2001 Door Catch Magnet Series 2001 to Current Item 22 ...

Page 23: ...ls 10x11 14 AA CMG Models 18 20 AA Models 10x11 14 BB TS Models 18 24 BB TS Models 34x24 BB TS 3 10 4 2 6 7 8 13 1 5 12 1 LOCK NUT LOCK NUT 6 7 8 13 10 3 4 11 12 5 1 2 6 7 8 13 10 10 3 10 LOCK NUT 6 7 8 4 6 7 8 11 12 5 1 13 13 4 5 12 1 13 3 10 6 LOCK NUT 7 8 3 10 6 7 8 13 4 7 8 12 12 10 13 10 12 1 6 7 8 5 LOCK NUT 11 ...

Page 24: ...Series 2005 Models 18 20 AA Series 2005 Models 18 24 BB TS Series 2005 34x24 BB TS Series 2005 Models 10x11 14 BB TS 2 10 6 LOCKNUT 6 7 8 14 3 10 6 LOCKNUT 6 7 8 14 3 2 10 6 LOCKNUT 8 14 3 7 8 14 12 12 11 TO GAS VALVE 10 LOCKNUT 6 7 8 10 6 LOCKNUT 7 8 11 TO GAS VALVE 3 14 10 LOCKNUT 6 7 8 10 6 7 8 11 14 9 3 10 LOCKNUT 6 7 8 11 14 14 ...

Page 25: ... 004341 LOCATED ON REAR DRAIN UNITS ONLY CONTROL PANEL AA CM GAS SERIES 2000 CONTROL PANEL AA CM GAS SERIES 2006 ITEM QTY DESCRIPTION P N A 1 HIGH LIMIT Resettable 1 800 KEATING BOTTOM MOUNT 034357 BACK MOUNT 004341 B 1 THERMOSTAT DIAL PLATE 250 375 F 058037 C 1 THERMOSTAT KNOB BLACK 060612 1 GAS FRYER THERMOSTAT 14AA 14CM 023145 10x11AA 18AA and Larger 035553 D 1 SWITCH ROCKER WHITE ON OFF 035030...

Page 26: ...REAR DRAIN UNITS ONLY CONTROL PANEL FRONT BACK PANEL FRONT DRAIN UNIT D A B C ITEM QTY DESCRIPTION P N A 1 THERMOSTAT DIAL PLATE 250 375 F 058037 B 1 THERMOSTAT KNOB BLACK 060612 C 1 GAS FRYER THERMOSTAT 14 BB TS IFM CPU 035574 10x11 18 and Larger 035575 D 1 SWITCH MELT IDLE FRY 032829 E 1 HIGH LIMIT Resettable 1 800 KEATING BOTTOM MOUNT 034357 BACK MOUNT 004341 F 1 FLAME SWITCH 038563 G 1 SWITCH ...

Page 27: ...32 O 1 RELAY DPDT 24VAC 030844 P 1 MAGNETIC SAFETY SWITCH 053777 Q 1 RECEPTACLE 125V not shown 011505 LOCATED ON REAR DRAIN UNITS ONLY ON 34x24 REAR DRAIN MODEL QTY 2 G F E A B C M L N O K H D J BACK PANEL REAR DRAIN UNIT ITEM QTY DESCRIPTION P N A 1 THERMOSTAT DIAL PLATE 250 375 F 058037 B 1 THERMOSTAT KNOB BLACK 060612 C 1 GAS FRYER THERMOSTAT 14 BB TS IFM CPU 035574 10x11 18 and Larger 035575 D...

Page 28: ...RMOSTAT 14 BB TS IFM CPU 035574 10x11 18 and Larger 035575 D 1 SWITCH ROCKER WHITE Replacement Kit 058328 E 2 DIGITAL TIMER 24V 056921 F SWITCH MELT IDLE FRY 032829 G 1 INDICATING LIGHT GREEN 021255 H 1 INDICATING LIGHT RED 021209 I 1 HIGH LIMIT Resettable 034357 J 1 FLAME SWITCH 038563 K 2 SWITCH ROCKER WHITE MOMENTARY Push to Light 032297 L 1 TRANSFORMER 24VAC 024032 M 2 RELAY DPDT 24VAC 030844 ...

Page 29: ...MP 1P 058219 R 1 RECEPTACLE 125V 011505 NOT SHOWN LOCATED ON REAR DRAIN UNITS ONLY NOT SHOWN BASKET LIFT UNITS ONLY BACK PANEL REAR DRAIN UNIT ITEM QTY DESCRIPTION P N A 1 SWITCH TOGGLE POWER 059141 B 1 INDICATING LIGHT CLEAR 057863 C 1 SWITCH TOGGLE PILOT 059142 D 1 INDICATING LIGHT AMBER 056588 E 1 SWITCH TOGGLE MELT FRY 059143 F 1 INDICATING LIGHT GREEN 056587 G 1 INDICATING LIGHT RED 057861 H ...

Page 30: ... F E G H D C A B P J K N L P N M J K Q L O BOOT BLACK WASHER SEALING RING HEX NUT INSERT F E F D C A B H I G CONTROL PANEL TS SPARK IGNITION FOR 34x24 MODEL SERIES 2007 FOR ALL OTHER MODELS SERIES 2009 CONTROL PANEL FRONT BACK PANEL FRONT DRAIN UNIT BACK PANEL REAR DRAIN UNIT ITEM QTY DESCRIPTION P N A 1 SWITCH TOGGLE POWER 059141 B 1 INDICATING LIGHT CLEAR 057863 C 1 SWITCH TOGGLE MELT FRY 059143...

Page 31: ...ER 24VAC 024032 M 1 RELAY DPDT 24VAC 030844 N 1 MAGNETIC DRAIN SWITCH 053777 O 1 RECEPTACLE 120V 011505 P 1 CIRCUIT BREAKER 4AMP 1P 058219 LOCATED ON REAR DRAIN UNITS ONLY NOT SHOWN LOCATED ON BASKET LIFT UNITS ONLY CONTROL PANEL FRONT BACK PANEL FRONT DRAIN UNIT BACK PANEL REAR DRAIN UNIT ITEM QTY DESCRIPTION P N A 1 SWITCH TOGGLE POWER 056056 B 1 SWITCH TOGGLE PILOT 056057 C 1 COMPUTER 058896 D ...

Page 32: ...MODULE 24V 028620 D SPARK ELECTRODE CABLE N A E 2 FLAME SWITCH 037406 NOT SHOWN ITEM QTY DESCRIPTION P N A 1 PILOT BURNER ELECTRODE NG 033772 PILOT BURNER ELECTRODE LP 037436 B 1 RUNNER PILOT TUBE 10 11 14 052891 18 052507 20 052892 24 052508 34 24 C 1 SPARK IGNITION MODULE 058439 D 1 SPARK ELECTRODE CABLE 037551 NOT SHOWN ITEM QTY DESCRIPTION P N A 1 SPARK IGNITION ELECTRODE 030253 B 1 RUNNER PIL...

Page 33: ... S S 054522 1 14 CONNECTOR 2 CIRCUIT PLUG 032208 1 CONNECTOR CONTACT PIN MALE 028309 2 15 PIN BASKET LIFT NON ROTATIONAL 054760 1 This circuit breaker can be found under the control panel on newer units BASKET LIFT POWER SUPPLY BOX BASKET LIFT ASSEMBLY not shown to scale Figure 6 Figure 7 Bottom View Top View 8 7 1 4 6 5 Top View Side View 2 3 Basket Lift Power Supply Box Basket Lift Assembly Hous...

Page 34: ...BUSHING STRAIN RELIEF 5 8 HOLE 000470 2 5 BUSHING STRAIN RELIEF 3 4 HOLE 033800 1 NOTE circuit breaker is located under the control panel TO LEFT BASKET TO CONTROL PANEL BACK TRAY TO RIGHT BASKET 1 3 4 4 5 2 TOP VIEW SIDE VIEW A C B D ITEM DESCRIPTION P N QTY A TRANSFORMER 120V 240V TO 24V 024032 1 B 2 PIN CONNECTOR 032207 1 C 9 PIN CONNECTOR 028303 1 D FAT MELT 24V 037470 1 ELECTRICAL BOX ASSEMBL...

Page 35: ...ONTROL PANEL INSERT MANIFOLD MILLIVOLT GAS VALVE THERMOPILE RUNNER PILOT TUBE COMPONENT CODES HL HI LIMIT SWITCH P POWER SWITCH TH THERMOSTAT COMPONENT CODES HL HI LIMIT SWITCH P POWER SWITCH RDS REAR DRAIN VALVE SWITCH TH THERMOSTAT WIRE COLOR CODES BL BLACK GR GREEN RD RED WH WHITE YL YELLOW NOTE ALL WIRES ARE 18 AWG AA 2007 ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER ...

Page 36: ...o com 34 COMPONENT CODES HL HI LIMIT SWITCH P POWER SWITCH TH THERMOSTAT WIRE COLOR CODES BL BLACK RD RED WH WHITE YL YELLOW NOTE ALL WIRES ARE 18 AWG AA 2010 ELECTRICAL ASSEMBLY FRONT DRAIN BB 2000 ELECTRICAL ASSEMBLY ...

Page 37: ...FAT MELT TIMING SWITCH BB 2000 ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER Electrical Assembly not Shown to Scale BB 2006 ELECTRICAL ASSEMBLY NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIMER SWITCH FS FLAME SWITCH HL HI LIMIT SWITCH HP HOLD TO LIGHT PILOT SWITCH MF ME...

Page 38: ...ITCH P POWER SWITCH PI PILOT ON LIGHT AMBER PO POWER ON LIGHT CLEAR R RELAY 24VAC RDS REAR DRAIN VALVE SWITCH TH THERMOSTAT TR TRANSFORMER WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIMER SWITCH HL HI LIMIT SWITCH MF MELT FRY SWITCH P POWER SWITCH PO POWER ON LIGHT CLEAR RDS REAR DRAIN VALVE SWITCH R RELAY ...

Page 39: ...CH P POWER SWITCH PI PILOT ON LIGHT AMBER PO POWER ON LIGHT CLEAR TH THERMOSTAT TR TRANSFORMER 34x24 BB 2007 ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIMER SWITCH FS FLAME SWITCH HL HI LIMIT SWITCH HP HOLD TO LIGHT PILOT S...

Page 40: ...DES BL BASKET LIFT CONNECTOR CB CIRCUIT BREAKER FR SE FILTER RECEPTACLE FS FLAME SENSOR GV GAS VALVE HL HI LIMIT SWITCH RDS REAR DRAIN SAFETY SWITCH R RELAY 24VAC TH THERMOSTAT T TIMER TR TRANSFORMER TS FAT MELT TIMING SWITCH NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW ...

Page 41: ...ITCH PI PILOT ON LIGHT AMBER R RELAY 24VAC RTC READY TO COOK LIGHT GREEN TH THERMOSTAT TR TRANSFORMER TS 2007 ELECTRICAL ASSEMBLY WITH SAFE EASY FILTER WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIMER SWITCH FS FLAME SWITCH HL HI LIMIT SWITCH HP HOLD TO LIGHT PILOT SWITCH MF MELT FRY SWITCH OMT OVER MAX TEM...

Page 42: ...NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC P POWER SWITCH PI PILOT ON LIGHT AMBER R RELAY 24VAC RTC READY TO COOK LIGHT GREEN TH THERMOSTAT TR TRANSFORMER TS 2007 ELECTRICAL ASSEMBLY SPARK IGNITION FRONT DRAIN NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIMER SWITCH H...

Page 43: ...RED P POWER SWITCH PI PILOT ON LIGHT AMBER R RELAY 24VAC RTC READY TO COOK LIGHT GREEN TH THERMOSTAT TR TRANSFORMER NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC 24 VDC TS 2009 ELECTRICAL ASSEMBLY SPARK IGNITION FRONT DRAIN WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIM...

Page 44: ...RE 18 AWG 120 VAC 24 VAC COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIMER SWITCH HL HI LIMIT SWITCH MF MELT FRY SWITCH OMT OVER MAX TEMP LIGHT RED P POWER SWITCH R RELAY 24VAC RDS REAR DRAIN VALVE SWITCH RTC READY TO COOK LIGHT GREEN TH THERMOSTAT TR TRANSFORMER TS 2007 ELECTRICAL ASSEMBLY SPARK IGNITION WITH SAFE EASY FILTER ...

Page 45: ...OWER ON LIGHT CLEAR R RELAY 24VAC RTC READY TO COOK LIGHT GREEN TH THERMOSTAT TR TRANSFORMER 34x24 TS 2007 ELECTRICAL ASSEMBLY FRONT DRAIN WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIMER SWITCH FS FLAME SWITCH HL HI LIMIT SWITCH HP HOLD TO LIGHT PILOT SWITCH MF MEL...

Page 46: ...OMT OVER MAX TEMP LIGHT RED P POWER SWITCH PI PILOT ON LIGHT AMBER PO POWER ON LIGHT CLEAR R RELAY 24VAC RTC READY TO COOK LIGHT GREEN TH THERMOSTAT TR TRANSFORMER WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIMER SWITCH FS FLAME SWITCH HL HI LIMIT SWITCH HP HOLD TO ...

Page 47: ...LIGHT CLEAR R RELAY 24VAC RDS REAR DRAIN VALVE SWITCH RTC READY TO COOK LIGHT GREEN TH THERMOSTAT TR TRANSFORMER 34 x 24 TS 2007 AND ALL TS MODELS 2009 ELECTRICAL ASSEMBLY SPARK IGNITION WITH SAFE EASY FILTER WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC COMPONENT CODES CB CIRCUIT BREAKER FM FAT MELT TIMER SWITCH F...

Page 48: ...IT SWITCH HP HOLD TO LIGHT PILOT SWITCH OMT OVER MAX TEMP LIGHT RED P POWER SWITCH PI PILOT ON LIGHT AMBER Rdc RELAY 24VDC TR TRANSFORMER WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC 24 VDC COMPONENT CODES CB CIRCUIT BREAKER CPU COMPUTER FS FLAME SWITCH HL HI LIMIT SWITCH HP HOLD TO LIGHT PILOT SWITCH OMT OVER MAX...

Page 49: ... VAC 24 VAC 24 VDC COMPONENT CODES CB CIRCUIT BREAKER CPU COMPUTER HL HI LIMIT SWITCH OMT OVER MAX TEMP LIGHT RED P POWER SWITCH Rdc RELAY 24VDC TR TRANSFORMER WIRE COLOR CODES BL BLACK BR BROWN BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW NOTES ALL WIRES ARE 18 AWG 120 VAC 24 VAC 24 VDC COMPONENT CODES CB CIRCUIT BREAKER CPU COMPUTER HL HI LIMIT SWITCH OMT OVER MAX TEMP LIGHT RED P POWER ...

Page 50: ...007 ALL FRYERS NOTES ALL WIRES EXCEPT 13 14 ARE 18 GAUGE WIRES 13 14 USE PN 028743 OR SIMILAR COMPONENT CODES L R 24V AC RELAYS RB RECTIFIER BRIDGE 4A 250V FOR FRYER EQUIPPED WITH CPU USE 24V DC RELAYS FOR ALL OTHERS USE 24V AC RELAYS TO CONNECTOR ON CONTROL PANEL ...

Page 51: ...S 2007 WIRE COLOR CODES BL BLACK BR BROWN B R BLACK RED BU BLUE GR GREEN OR ORANGE RD RED WH WHITE YL YELLOW 120 VAC 24 VAC VDC NOTES ALL WIRES ARE 18 AWG THIS DIAGRAM SHOWN 120VAC SUPPLY VOLTAGE COMPONENT CODES A ACTUATOR BR BRIDGE RECTIFIER R RELAY 24VAC TR TRANSFORMER 100VA ...

Page 52: ......

Page 53: ......

Page 54: ...RRANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE Have your serial and model number available when ordering parts As continuous product improvement occurs specifications may be changed without notice KEATING LIMITED WARRANTY CARD FRYER GRIDDLE CUST...

Reviews: