1-800-KEATING
|
GAS FRYER - SERIES 2009
7
SERIES 2006 BB MODELS
OPERATING INSTRUCTIONS
DO NOT START FRYER WITHOUT FIRST FILLING FRY
POT.
START-UP PROCEDURE
1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “ON” position.
The power ON light will illuminate.
3. Hold the “PUSH TO LIGHT” switch over until
the amber “PILOT ON” light comes on. Release
switch.
4. Set thermostat to desired temperature.
5. Set “MELT-FRY” switch to “FRY.” The burners
will come on. Select “MELT” with solid shortening
until liquid shortening is 1" from full, then switch
to the “FRY” position after packing shortening
around burner tubes.
SHUTDOWN PROCEDURE
1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “OFF” position.
3. Check to make sure all burners and pilot are
extinguished.
SERIES 2006 BB SPARK IGNITION MODELS
OPERATING INSTRUCTIONS
DO NOT START FRYER WITHOUT FIRST FILLING FRY
POT.
START-UP PROCEDURE
1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “ON” position.
Its light will come on.
3. Set thermostat to desired temperature.
4. Set “MELT-IDLE-FRY” switch to “FRY” with oil in
the fry pot. The burners will come on.
5. Set “MELT-FRY” switch to “FRY.” The burners
will come on. Select “MELT” with solid shortening
until liquid shortening is 1" from full, then switch
to the “FRY” position after packing shortening
around burner tubes.
SHUTDOWN PROCEDURE
1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “OFF” position.
3. Check to make sure all burners and pilot are
extinguished.
SERIES 2000 TS MODELS
OPERATING INSTRUCTIONS
DO NOT START FRYER WITHOUT FIRST FILLING FRY
POT.
START-UP PROCEDURE
1. Set “MELT-IDLE-FRY” switch to “IDLE” position
and thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “ON” position.
Its green light and the timers will come on.
3. Light constant pilot located on left side of pilot
runner tube.
4. Hold the “PUSH TO LIGHT” switch for 30
seconds. The pilot runner tube will light.
5. Set thermostat to desired temperature.
6. Set “MELT-IDLE-FRY” switch to “FRY” with oil in
the pot. The burners will come on. Select “MELT”
with solid shortening until liquid shortening is 1"
from full mark, then switch to the “FRY” position
after packing shortening around burner tubes.
SHUTDOWN PROCEDURE
1. Set “MELT-IDLE-FRY” switch to “IDLE” position
and thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “OFF” position.
Its green light will go off.
3. Check to make sure all burners and pilot are
extinguished.
BB CONTROL PANEL – SERIES 2006
BB SPARK IGNITION CONTROL PANEL –
SERIES 2006
TS CONTROL PANEL – SERIES 2000