keatingofchicago.com
8
SERIES 2006 TS MODELS
OPERATING INSTRUCTIONS
DO NOT START FRYER WITHOUT FIRST FILLING FRY
POT.
START-UP PROCEDURE
1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “ON” position.
Its green light and the timers will come on.
3. Light constant pilot located on left side of pilot
runner tube.
4. Hold the “PUSH TO LIGHT” switch for 30
seconds. The pilot runner tube will light.
5. Set thermostat to desired temperature.
6. Set “MELT-IDLE-FRY” switch to “FRY” with oil in
the fry pot. The burners will come on. Select
“MELT” with solid shortening until liquid
shortening is 1" from full mark, then switch to
the “FRY” position after packing shortening
around burner tubes.
SHUTDOWN PROCEDURE
1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “OFF” position.
Its green light will go off.
3. Check to make sure all burners and pilot are
extinguished.
SERIES 2009 TS SPARK IGNITION MODELS
OPERATING INSTRUCTIONS
DO NOT START FRYER WITHOUT FIRST FILLING FRY
POT.
START-UP PROCEDURE
1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “ON” position.
Its green light and the timers will come on.
3. Set thermostat to desired temperature.
4. Set “MELT-IDLE-FRY” switch to “FRY” with oil in
the fry pot. The burners will come on. Select
“MELT” with solid shortening until liquid
shortening is 1" from full mark, then switch to
the “FRY” position after packing shortening
around burner tubes.
SHUTDOWN PROCEDURE
1. Set thermostat to the “OFF” position.
2. Turn “MAIN POWER” switch to the “OFF” position.
Its green light will go off.
3. Check to make sure all burners and pilot are
extinguished.
TS CONTROL PANEL – SERIES 2009
TS CONTROL PANEL – SERIES 2006
TS SPARK IGNITION CONTROL PANEL
SERIES 2009
TS SPARK IGNITION CONTROL PANEL
SERIES 2006