X
1
56,5 mm
X
2
56,5 mm
20 mm
74
0,2 - 0,3 mm
A
C
B
137 mm
133 mm
BQ3
X
Y
BQ2 - X - AXIS
BQ2
ES-505
1-74
Released: 01/2018
E-mail: [email protected]; webside: amfreece.com
Phone: +420 582 309 146; Fax: +420 582 360 606
E - STANDARD MACHINE ADJUSTMENT
6. SETTING BED PLATE
The home position of the bed plate
is given with the position of sensor
screens
BQ2
for axis
X
and
BQ3
for axis
Y.
Sensor screen screws
are locked with yellow color by the
manufacturer. In the warranty period
this operation can therefore be done
only by the AMF REECE service
mechanic.
6.1. To get access to
BQ2
sensor
screen, dismantle the right bedplate
cover
1
. Loosen the screew
3
and
set up the sensor plate
2
approximately to 10 mm from the
console edge
4
. Check the correct
setting by bringing the machine into
home position with pushing the
button
. The distance from
the left and right side of the bedplate
to the gauge must be same (X1 =
X2) - (see picture
B
).
6.2. To get access to
BQ3
sensor
plate, dismantle the cover
1
.
Loosen the screew
3
and set up
the sensor plate
2
approximately
to 133 mm from the bearing support
8
. The belt holder
9
is preset to
137 mm from the bearing support
8
(see pic.
C
).
6.3. Set up the distance of sensors
from screens to 0,2 - 0,3 mm (see
pic.
A
). If the value exceeds, the
electrical system does not work
correctly.
6.4. Correct the position of the
sensor screen
BQ3
, if the dimension
from the inner prick in the eye top
and the needle center is not 74 mm.