ES-505
1-105
Released: 01/2018
E-mail: [email protected]; webside: amfreece.com
Phone: +420 582 309 146; Fax: +420 582 360 606
F - STANDARD MACHINE ADJUSTMENT INDEXER MODEL
1. SETTING UP THE HEIGHT OF CLAMPING FEET
In order for the Indexer to function correctly, it is important to set up correct height of Indexer clamping feet above
the desktop cover.
1.1. Loose clamp holders screws
1
on the left and right side of the Indexer.
1.2. Set up a gap of 0,5 - 0,7 mm between feet
2
and desktop cover
3
,feeler gauge can be used.
1.3. Verify the setting by pressing the button
. The device must move freely without stopping.
1.4. If the device stops, it is necessary to increase the gap between feet and desktop according to instructions
in 1.1, 1.2.
Note
:
The above-mentioned adjustment is necessary every time you change the distance between the clamping feet
according to the size of workpiece and number of buttonholes sewn.