D - MACHINE CONTROLS
4. INDEXER MODEL
4.1.
Indexer Main Screen Description
The main screen appears on the display after turning the indexer on described in chapter D 2.7. The main screen
contains the standard buttons described in chapter D 1.1. - D 1.2. and also several further buttons.
•
Press button
1
to set the Indexer direction.
– machine starts from the left side.
– machine starts from the right side.
– machine starts alternatively from the left and from the right. Select the initial side using button
2
.
•
– Indexer angle info, showed for Angle Indexer machine only
•
Press button
3
to shift indexer by 1 position forward manually. E.g., using this option one can start sewing from
the 3
rd
position of the indexer cycle.
•
When the indexer cycle program number
4
is set to 0, the same buttonhole is sewn repeatedly without indexer
clamp-feet movement (Indexer is deactivated).
When the indexer cycle program number
4
is higher than 0, indexer is activated → after sewing of the 1
st
buttonhole indexer shifts by the set distance
5
and the next sewing starts at the 2
nd
position, etc. One can
program up to 50 different indexer cycles.
•
Press button
6
to interrupt indexer cycle. Button is available only during BH sewing.