2.3.2. SETTING PARAMETERS ROUND BUTTONHOLE
Press the button
1
on the main screen of the round buttonhole. Round buttonhole parameters screen comes up at
AF model. Here you can choose a buttonhole without eye, with eye or round buttonhole (buttons
2
).
Press the button
3
and the round buttonhole is highlighted active.
Press the button
4
and set the inner buttonhole diameter within the range 2,0 - 7,0 mm.
Press the button
5
and set the number of stitches in the buttonhole within the range 10 - 60.
Press the button
6
a set the bite within the range ± 0,3 mm.
Press the button
7
and set feeding in the buttonhole (stitch angle) within the range 50 - 100 %.
Press the button
8
and define the number of oversewing stitches at the end of the buttonhole, range 0 - 9.