ES-505
1-110
G - MACHINE MAINTENANCE
Released: 01/2018
E-mail: [email protected]; webside: amfreece.com
Phone: +420 582 309 146; Fax: +420 582 360 606
1.1.2.
Filter unit cleaning and maintenance
a) Connect the machine to the air supply.
b) Check the level of condensation
1
in the reservoir
2
. The liquid level must not get more than 10 mm under the
filter sleeve
3
. The height is marked by the lowest nut ferrel
4
.
c) Press drain valve
5
and drain condensation out
1
.
d) Disconnect air supply.
In case of airflow decline, replace the filter sleeve
3
. Filter sleeve must be changed after two years of machine
operation at the latest or every time the pressure drops down to 0,1MPa.
How to exchange filter sleeve:
c) Push latch
6
in the direction of the arrow and turn reservoir
2
of 45° any side you like.
d) Pull reservoir
2
out in the direction of the arrow.
e) Loosen nut
4
by turning it counter-clockwise.
f) Remove filter sleeve
3
and put new one.
g) Put filter together.
1.1.3.
Needle check
a) Loosen screew
1
and take needle out
2
.
b) Check that needle tip is not damaged
c) Roll the needle on the flat board to see whether the needle is not bent
d) Replace the needle with a new one if damaged or bent!
e) After checking put the needle
2
back into machine – see chapter
C1.1
.