E - STANDARD MACHINE ADJUSTMENT
29.3. GIMP
Turn the tensioner nut
1
clockwise to increase the
upper thread tension and anticlockwise to reduce
it. Gimp tension is in operation only with CT version
to adjust the gimp length coming out the stitch
plate.
CAUTION
!
Tension tight too much in the tensioner can cause
deformation of a buttonhole in the eye.
It is not necessary to adjust any bottom thread
tension at
AF
versions.
CT
and
LTT
versions need to have gimp sufficiently
released, which ensures the pneumatic cylinder
2
and release lever
3
. The length of the release
gimp can be adjusted by the side guide
4
. To
change the position of the guide
4
loosen the
screws
5
and move the guide
4
to the required
position. Tighten the screws
5
.
Note
:
At
CT
versions set up the thread tension and droof
so that the minimal gimp length coming out the
stitch plate
6