![Amazone AD 3000 Super Classic Line Operating Manual Download Page 57](http://html1.mh-extra.com/html/amazone/ad-3000-super-classic-line/ad-3000-super-classic-line_operating-manual_2919699057.webp)
Structure and function
AD 3000 Super BAH0107-0 02.20
57
5.7
Metering
The seed is carried in the seed hopper. The seed goes into the seed housing through adjustable
openings (Fig. 37/1). Each seed housing has an opening. The opening size is adjusted with the sliding
shutters.
The seed is metered either by the normal seed
metering wheel (Fig. 37/2) or the fine seed
metering wheel. The normal seed metering
wheel can be immobilised for fine seeds.
For normal seeding, both seed metering wheels
rotate.
The seed metering wheel conveys the seed to
the edge of the bottom flap (Fig. 37/3). The
metered seed travels through the seed tube to
the seeding coulter.
Fig. 37
Before beginning seeding,
the following values, depending on the seed type, must be taken from the Table "Setting values"
(page 58) and set:
Normal seed metering wheel, fine seed metering wheel or bean metering wheel
Sliding shutter position
Bottom flap position
Agitator shaft support.
the seeding rate must be calibrated.
If the seed is not listed in the "Setting values" table (page 58), take the setting values for a seed with a
similar shape and size.