CP-3000 User’s Guide
6-11
Printer or printer carriage is damaged. Contact your local Amano
dealer.
The slider on the printer carriage is not moving correctly due to a
missing black plastic bushing in the small hole of the right printer
frame. Contact your local Amano dealer.
The ribbon cassette is not seated correctly in the printer carriage.
Reinstall the ribbon cassette.
Run the
Color Change Test
in the
Diagnostics
menu.
Printer or printer carriage is damaged. Contact your local Amano
dealer.
Weak or Light Printing
Please refer to
Printing or Ribbon Error Message, Err1
section of this
chapter for troubleshooting weak or light printing problems.
Diagnostics
The
Diagnostics
menu is used to run specific diagnostic routines for
troubleshooting and determining the condition of your CP-3000.
The
Diagnostics
menu is accessed by entering the
Program Mode
, and
pressing the
FUNCTION
key until the LED Test menu item appears in
the display and the last LED indicator is illuminated.
The general guidelines for the
Diagnostics
menu are as follows:
Each test is indicated by a specific number (refer to the
Programming Guide
) flashing in the display.
To select and start a test, press the
YES
key.
To stop a test press the
YES
key again. A beep will sound and
the test number will flash in the display.
Press the
NO
key to move to the next test.
Press the
FUNCTION
key to leave the
Diagnostics
menu.
Summary of Contents for CP-3000
Page 1: ...CP 3000 Electronic Time Recorder User s Guide ...
Page 6: ...iv CP 3000 User s Guide This page intentionally left blank ...
Page 22: ...2 12 CP 3000 User s Guide This page intentionally left blank ...
Page 30: ...3 8 CP 3000 User s Guide This page intentionally left blank ...
Page 56: ...5 4 CP 3000 User s Guide This page intentionally left blank ...
Page 74: ...7 2 CP 3000 User s Guide ...
Page 75: ......