2-2
CP-3000 User’s Guide
Front Cover
Removal
The front cover must be removed to connect the Full Power Reserve
Battery and connect the external signal line (Model A051 and A056 only)
for the CP-3000. To do so, perform the following steps:
Step 1
. Disconnect the power cord from the power source if applicable.
Step 2
. Remove the top cover.
Step 3
. Lay the unit face up on a flat surface.
Step 4
. Facing the front of the unit, remove the two Phillips head screws
in the upper corners of the housing.
Step 5
. Press both of your hands flat against the sides of the front cover.
Step 6
. Pivot the front cover towards you and remove. Set face up on a
flat surface.
Installation
Step 1
. With the front cover on a flat surface and facing up, press both of
your hands flat against the sides.
Step 2
. Facing the bottom of the unit, set and align the tabs on the
bottom of the front cover with the grooves on the housing.
Step 3
. Pivot the front cover towards the housing, push it down in place,
then secure it with the two Phillips head screws.
Step 4
. Re-install the top cover. If necessary, reconnect the power cord
to the power source.