2-8
CP-3000 User’s Guide
Note:
This procedure must be performed with the power cord
disconnected from the power source.
To connect the Full Power Reserve Battery perform the following steps:
Step 1
.
Remove the top cover.
Step 2
.
Remove the front cover.
Step 3
.
Locate the battery cable. This is a pair of red and black wires
protruding from the chassis.
Step 4
.
Connect the battery cable to
CN13
on the PC Board. If the
battery is properly connected, the following will occur:
the LCD will display the default time in the “As Shipped”
(12 hour) format:
an LED indicator will blink, and
the ribbon carriage will cycle
Step 5
. Replace the front cover.
Step 6
. Replace the top cover.
Note:
The “As Shipped” time display format setting is configured at the
factory. If the CP-3000 should lose its configuration, the time will
be displayed in the default (24 hour) time format when the
battery is connected.