A
Appendix
83
ML-7 Series/ML-9001A
Appendix
A
Troubleshooting
18
BMP Error:
No Parts
-
Register parts.
19
Cursive Text
Unregistered
-
No cursive text data has been registered.
Register the data.
20
Battery Voltage Drop
-
The system battery voltage is low.
Replace the battery.
21
Cover Open
Interlocked with Fiber
-
The head cover or control cover has come off.
Attach the cover. Otherwise, the fiber connector has been
disconnected. Connect the fiber interlock connector.
22
Emergency Stop ON
-
An emergency stop signal has been inputted. Close the external
emergency stop input circuit of the external I/O control connector.
Also release the Emergency Stop button on the marker or control
panel.
30
LD Power Supply
Overheat
Off
A temperature error has occurred with the LD power supply.
•
Clean the Control Unit air filter.
•
Ensure that the temperature around the equipment is between
5 and 35
°
C.
•
Wait at least ten minutes after restoring the power before starting
the laser.
If the error persists following these measures, contact us.
31
LD Current Error
Off
An LD current error has occurred.
If the error persists after restarting, contact us.
32
LD Voltage Error
Off
An LD voltage error has occurred.
If the error persists after restarting, contact us.
33
Peltier Power Supply
Overheat/
Control Error
Off
A temperature error with the LD Peltier power supply or a Peltier
control error has occurred.
If the error persists after restarting, contact us.
34
Crystal Peltier Power
Supply Overheat
Off
A temperature error has occurred with the crystal Peltier power
supply.
If the error persists after restarting, contact us.
35
LD Power Supply
Error
(ML-7064A)
Off
An LD power overcurrent or overvoltage has occurred, the unit has
overheated, or the fan has stopped. If the error persists after
restarting, contact us.
36
-15V Power Supply
Error
(ML-7112AH)
Off
A -15 V power supply error has occurred. If the error persists after
restarting, contact us.
40
RF Progressive Wave
Weak
Off
The RF unit is damaged.
If the error persists after restarting, contact us.
41
RF Progressive Wave
Excessive
Off
The RF unit is damaged.
If the error persists after restarting, contact us.
42
RF Reflective Wave
Excessive
Off
The RF reflective wave is too strong.
Make sure the RF cable is connected securely to the Control Unit and
Head Unit.
If the error persists after you connect the cable correctly and restart,
contact us.
50
RF Temperature
Error
Off
An RF temperature error has occurred.
If the error persists after restarting, contact us.
Error
Code
Error Details
LD
Cause and Corrective Action