Chapter
3
23
ML-7 Series/ML-9001A
3.1 Installation Requirements
■
Head Unit
Refer to the following figure when installing the Head Unit.
Install the Head Unit in a well-ventilated location. Because marking may produce dust and particulates,
we recommend installing a dust collector.
Required Clearance and Mass Support:
ML-7111A
ML-7112AH
ML-9001A
ML-7064A
A. Clearance on top
At least 250 mm
At least 300 mm
At least 250 mm
At least 300 mm
B. Clearance on right
At least 200 mm
At least 300 mm
At least 200 mm
At least 300 mm
C. Clearance on left
At least 300 mm
At least 300 mm
At least 300 mm
At least 300 mm
D. Clearance in back
At least 200 mm
At least 360 mm
At least 200 mm
At least 200 mm
E. Clearance in front
-
At least 150 mm
-
At least 300 mm
F. Mass
13 kg
9.5 kg
13 kg
26 kg
Air intake/exhaust
Back/left side
Right side/right side
Back/left side
None
・
Ensure the bending radius of the optical fiber at the back of Head Unit and Control Unit is at
least 150 mm.
・
When moving the Head Unit, support the unit in front and back to avoid touching the lens
(ML-7111A, ML-9001A, and ML-7064A). With the ML-7112AH, use both hands to hold the
handles on both sides. Do not hold it by the optical fiber or other cables.
ML-7111A, ML-9001A, and ML-7064A
ML-7112AH
A
(Front)
(Back)
Optical Fiber
Bending
Radius:
150 min.
C
B
D
E
Lens
F