A
Appendix
82
ML-7 Series/ML-9001A
Appendix
A
Troubleshooting
If any problems occur with the equipment, error details are displayed on the computer or the control
panel.
Refer to the following error code list when troubleshooting problems.
A.2 Error Codes
Error
Code
Error Details
LD
Cause and Corrective Action
01
1st Standard Font
Unregistered
-
The first standard font has not been registered.
Register the font.
02
2nd Standard Font
Unregistered
-
The second standard font has not been registered.
Register the font.
03
Part Unregistered
-
The part data is not registered.
Register the data.
04
Serial No.
Unregistered
-
The serial number data has not been registered.
Register the data.
05
Common Variable
Data Unregistered
-
If this message is displayed, contact us.
06
Variable Data
Unregistered
-
The variable data has not been registered.
Register the data.
07
Layout Data
Unregistered
-
The layout data has not been registered.
Register the data.
Choose a starting number other than "0."
08
Loops (100)
Excessive
-
If this message is displayed, contact us.
09
Marking Speed Error
-
Invalid marking speed setting.
Adjust the marking speed.
10
ACK Timeout
-
No ACK response (indicating completion) was received from the
transfer unit within the allotted time.
Check the transfer unit.
11
Layout/
Command Error
-
Font or layout error. The font data or layout data is broken.
After restarting the marker and your computer, transfer the font data
or layout data again.
12
Layout/
Parameter Error
-
Layout error.
After restarting the marker and your computer, transfer the layout
data again.
13
Layout/
Insufficient Command
Error
-
14
Serial Number Data
Overflow
-
The maximum (or minimum) number has been reached in serial
number marking.
Check the details and reset the current value.
15
Character Command
Error
-
A character data error has occurred.
After restarting the marker and your computer, transfer the character
data.
16
Marking Area Error
-
Layout error.
After restarting the marker and your computer, transfer the layout
data.
17
LD Current is Limited
Warning
-
The LD current has been limited due to exceeding the maximum
current value limit. Check the current LD value or adjust the
maximum current value if necessary.
Summary of Contents for ML-7 Series
Page 4: ......
Page 8: ...4 ML 7 Series ML 9001A Contents...
Page 82: ...Chapter 4 78 ML 7 Series ML 9001A Chapter 4 Maintenance...
Page 83: ...Appendix...