Chapter
4
71
ML-7 Series/ML-9001A
4.7 Chiller Unit Maintenance and Inspection (ML-7064A Only)
4.7.8 Cleaning the Chiller Unit Air Filter
Clean the air filter in the Chiller Unit once a month as follows:
1
Pull out the air filter cover at the front of the Chiller Unit.
2
Pull the knob on the bottom of the air filter to remove it. Clean the filter with a vacuum cleaner.
3
After cleaning it, return the air filter to its original position and attach the air filter cover.
・
When cleaning the air filter, be careful not to bend the air condenser fins. If the fins
are bent, it may impair the Chiller Unit's cooling capacity.
・
If the air filter becomes dirty, the coolant pressure may rise, thus causing chiller
problems. Keep the filter clean.
Air condenser
(on the interior side of
the air filter)
Knob
Air filter
Filter cover
Knob
Air filter
Summary of Contents for ML-7 Series