Chapter
3
24
ML-7 Series/ML-9001A
Chapter
3
Installation
Keep the following points in mind when installing the Head Unit:
•
The following work distances represent the distance from the bottom surface of the lens's flange to
the focal position. Because the work distance varies depending on individual differences in equipment
and marking conditions, ensure the Head Unit is installed to allow adjustment in a range of
±
5 mm
relative to these values.
* On the ML-7112AH, the f
lens is concealed inside the Head Unit.
•
Install the Head Unit so that you can make level adjustments and keep it level after installation.
•
For the Head Unit mounting platform, use a sheet of metal at least 10 mm thick.
•
Isolate the mounting platform from vibration.
Although vibration of 0.1 G or less during operation is acceptable, even subtler vibration may affect or
distort marking or damage the equipment. Keep the mounting platform separate from conveyor lines
or other equipment to prevent vibration and impact.
•
When marking highly reflective materials (such as gold, silver, copper, aluminum, steel, or stainless
steel), do not position them about the marking origin. Also, make sure the focal distance is correct.
Positioning highly reflective materials about the marking origin or positioning workpieces closer than
the lens focal distance may cause the laser to reflect from the workpiece and burn the inside of the
Head Unit.
(ML-7064A only)
To prevent altering the optical axis by twisting the Head Unit when tightening the mounting
fixtures, loosen the fixtures on the Head Unit side, then tighten only the mounting platform
fixtures before tightening the Head Unit fixtures.
Lens
Lens Used
Approx. Work Distance
ML-7111A
ML-7112AH (*)
ML-9001A
ML-7064A
f75
f = 75 mm
93 mm
-
-
93 mm
f100
f = 100 mm
110 mm
-
95 mm
107 mm
f150
f = 150 mm
170 mm
-
-
170 mm
f160
f = 160 mm
175 mm
175 mm
175 mm
-
f254
f = 254 mm
299 mm
-
277 mm
-
f270
f = 270 mm
313 mm
-
-
313 mm
f300
f = 300 mm
-
-
327 mm
-
f350
f = 350 mm
-
-
-
411 mm
f410
f = 410 mm
-
-
434 mm
-
f420
f = 420 mm
494 mm
-
-
-
1) Loosen the mounting
fixtures.
2) Tighten the fixtures on
the mounting board.
3) Tighten the fixtures
on the Head Unit.