MEA-100B
14. External Communication Function
14-9
Item
Contents
Character
string
Range
17
[NCL] No-current detecting
level CC:2 1ST
nn,
00 to 10 (%)
18
[NCL] No-current detecting
level CC:2 2ND
nn,
00 to 10 (%)
19
[NCL] No-current detecting
level CC:3 HALF
nn,
00 to 10 (%)
20
[NCI] No-current neglecting
cycle
nn.n,
00.0 to 10.0 (CYC)
(in 0.5 increment)
21
[START PARITY] #4 screen
E02
n,
0: Caution 1: Trouble
22
[NO CURRENT] #4 screen
E04
n,
0: Caution 1: Trouble
23
[LOW CURRENT] #5 screen
E05
n,
0: Caution 1: Trouble
24
[HIGH CURRENT] #5 screen
E06
n,
0: Caution 1: Trouble
25
[FULL WAVE] #5 screen E07
n,
0: Caution 1: Trouble
2: No Trouble-Caution
26
[STEP END] #5 screen E08
n,
0: Caution 1: Trouble
27
[CYCLE TROUBLE] #6 screen
E11
n
0: Caution 1: Trouble
Screen 05 (Monitor data) Specific data in accordance with Schedule No. (Schedule
No.: 01 to 31)
Item
Contents
Character
string
Range
1
WELD1 Time
nn,
00 to 99 (CYC)
2
WELD1 Current
n.nn,
0.00 to 9.99 (kA)
3
WELD1 Conduction Angle
nnn,
000 to 180 (°)
4
WELD2 Time
nn,
00 to 99 (CYC)
5
WELD2 Current
n.nn,
0.00 to 9.99 (kA)
6
WELD2 Conduction Angle
nnn,
000 to 180 (°)
7
Valve1 Stepper No.
n,
1 to 5
8
Valve1 Stepper Count
nnnn,
0000 to 9999
9
Valve2 Stepper No.
n,
1 to 5
10
Valve2 Stepper Count
nnnn,
0000 to 9999
11
Total Count
nnnnnnnn 00000000 to 99999999
Screen 06 (Error data) Common data (Schedule No.: 00)
•
Error data confirmation (Data reading only)
Item
Contents
Character
string
Range
1
Error code 1
nnn,
E01 to E15
2
Error code 2
nn,
01 to 15
3
Error code 3
nn,
01 to 15
4
Error code 4
nn,
01 to 15
5
Error code 5
nn,
01 to 15