MEA-100B
14. External Communication Function
14-4
2) Error Data
Data strings:
!01 01:E03,04,05,06,07,08,09,10[CR][LF]
A B C D E F G H I J
Item
Contents
Character
string
Range
A
Device No.
nn
01 to 31
B
Schedule No.
nn,
01 to 31
C
*1
Error code 1
nnn,
E01 to E15
D
*1
Error code 2
nn,
01 to 15
E
*1
Error code 3
nn,
01 to 15
F
*1
Error code 4
nn,
01 to 15
G
*1
Error code 5
nn,
01 to 15
H
*1
Error code 6
nn,
01 to 15
I
*1
Error code 7
nn,
01 to 15
J
*1
Error code 8
nn
01 to 15
*1 The number of error codes is of eight max. In the case of only one error
code, the error codes D to J are omitted.
“E” is affixed only to Error code 1.
*2 Error codes are transmitted when errors are detected.
For E05 to E08, however, the error is transmitted after the monitored data
is transmitted.