MEA-100B
7. Basic Operation
7-12
(8) Current Monitor Display Screen
The current monitor display screen indicates the welding currents, the weld time
and the conduction angle.
Press the [MENU] key to go to the current monitor display screen.
(Switching off power clears the monitored currents.)
Multi-Cycle Welding
Item
Setting Range/Display
a Weld force number Indicates the weld force number used for welding.
b W1 weld time
Indicates the monitored weld time of W1.
c W1 current
Indicates the average effective current during W1.
d W1 conduction
angle
Indicates the monitored average conduction angle of
W1.
e Schedule Number Indicates the number of the schedule used for welding.
f W2 weld time
Indicates the monitored weld time of W2.
g W2 current
Indicates the average effective current during W2.
h W2 conduction
angle
Indicates the monitored average conduction angle of
W2.
Single-Cycle Welding
Item
Setting Range/Display
a Weld force number Indicates the weld force number used for welding.
b 1ST current
Indicates the effective current in the 1ST half-cycle.
c 1ST conduction
angle
Indicates the monitored conduction angle in the 1ST
half-cycle.
d Schedule Number Indicates the number of the schedule used for welding.
e 2ND current
Indicates the effective current in the 2ND half-cycle.
f 2ND conduction
angle
Indicates the monitored conduction angle in the 2ND
half-cycle.
1
W1 10 0.95kA 147
°
01 W2 00 0.00kA 000
°
e
f
g
h
a
b
c
d
1
1ST
0.55kA 101
°
01
2ND
0.57kA 104
°
d
e
f
a
b
c