MEA-100B
7. Basic Operation
7-8
(4) Ready for Welding (Turning on the [READY] Lamp)
By following steps
to
below, the [READY] lamp lights and the
MEA-100B
is
brought into the READY state (to flow the welding current).
If any fault occurs, rectify the fault and then clear fault output. (For clear of fault
outputs, see
12. Troubleshooting
.)
Press the [WELD] key on the panel. The [WELD] lamp (green) lights and the
MEA-100B
is brought into ready state for WELD ON.
Close Terminals 25 and 26 ([WELD ON/OFF]) on the rear panel I/O terminal
strip. (For details, see 10. (2).)
Press and hold down the [WELD] key for at least a second or open Terminals 25
and 26 on the rear panel I/O terminal strip to cancel the welding READY state.
The [WELD] lamp and the [READY] lamp are turned off.
WELD
MENU
READY
START
GOOD
SET 1
SET 2
ME