(5) Data Code Table
Screen 01 (SCHEDULE data) Specific data in accordance with Schedule No.
(Schedule No.: 01 to 31)
Item
Contents
Character
string
Range
1
[SQ] Squeeze
nn,
00 to 99 (CYC)
2
[UP1] Upslope 1
n,
0 to 9 (CYC)
3
[W1] Weld 1
nn,
00 to 99 (CYC)
4
[CO] Cool
nn,
00 to 99 (CYC)
5
[UP2] Upslope 2
0 to 9 (CYC)
6
[W2] Weld 2
nn,
00 to 99 (CYC)
7
[DWN] Downslope
n,
0 to 9 (CYC)
8
[HLD] Hold
nn,
00 to 99 (CYC)
9
[CURR.1] Current 1
n.nn,
0.20 to 9.99 (kA) (CC:0)
nn.n,
10.0 to 99.9 (%) (CC:1)
10
[CURR.2] Current 2
n.nn,
0.20 to 9.99 (kA) (CC:0)
nn.n,
10.0 to 99.9 (%) (CC:1)
11
[1ST] First half wave current
nn.n,
10.0 to 99.9 (%) (CC:2)
12
[2ND] Second half wave current
nn.n,
10.0 to 99.9 (%) (CC:2)
13
[HALF] Weld current
nn.n,
10.0 to 99.9 (%) (CC:3)
14
[PULSATION] Pulsation
n,
1 to 9
15
[SOLENOID] Weld force output
n
1, 2
Screen 02 (Upper/lower setting data) Specific data in accordance with Schedule No.
(Schedule No.: 01 to 31)
Item
Contents
Character
string
Range
1
[W1 H] Weld 1 Current Upper Limit nn,
00 to 49 (%)
n.nn,
0.00 to 9.99 (kA)
2
[W1 L] Weld 1 Current Lower Limit nn,
00 to 49 (%)
n.nn,
0.00 to 9.99 (kA)
3
[W2 H] Weld 2 Current Upper Limit nn,
00 to 49 (%)
n.nn,
0.00 to 9.99 (kA)
4
[W2 L] Weld 2 Current Lower Limit nn,
00 to 49 (%)
n.nn,
0.00 to 9.99 (kA)
5
[1ST H] Weld 1 Current Upper Limit n.nn,
0.00 to 9.99 (kA)
6
[1ST L] Weld 1 Current Lower Limit n.nn,
0.00 to 9.99 (kA)
7
[2ND H] Weld 2 Current Upper
Limit
n.nn,
0.00 to 9.99 (kA)
8
[2ND L] Weld 2 Current Lower Limit n.nn,
0.00 to 9.99 (kA)
9
[HALF H] Weld Current Upper Limit n.nn,
0.00 to 9.99 (kA)
10
[HALF L] Weld Current Lower Limit n.nn
0.00 to 9.99 (kA)