MEA-100B
1. Special Precautions
1-4
(2) Precautions for Handling
■
When transporting or moving the Power Supply, do not lay it down. Also, handle
the Power Supply with care so as not to make an impact such as drop on it.
■
Install this Welding Power Supply on a firm, level, horizontal surface. If it is
inclined, malfunction may result.
■
Do not install this Welding Power Supply in the following:
・
Damp places where humidity is higher than 90%,
・
Hot or cold places where temperatures are above 45°C or below 0°C,
・
Places near a high noise source,
・
Places where chemicals are handled,
・
Places where water will be condensed,
・
Dusty places, and
・
Places at an altitude above 1000 meters.
■
Clean the outside of the Welding Power Supply with a soft, dry cloth or one wet
with a little water. If it is very dirty, use diluted neutral detergent or alcohol. Do not
use paint thinner, benzine, etc., since they can discolor or deform the Welding
Power Supply.
■
Do not put a screw, a coin, etc., in the Welding Power Supply, since they can
cause a malfunction.
■
Operate the Welding Power Supply according to the method described in this
operation manual.
■
Operate the switches and buttons carefully by hand. If they are operated roughly
or with the tip of a screwdriver, a pen, etc., this will cause malfunction or damage.
■
Operate the switches and buttons one at a time. If two or more of them are
operated at a time, the Power Supply may have trouble or may be broken.
■
The Power Supply is not equipped with auxiliary power such as an outlet for
lighting.
■
The welding head, the welding transformer, the secondary cable for connecting
the welding head with the welding transformer, and the connecting cable for
connecting the welding transformer with the Power Supply are separately needed
to use the Power Supply.
■
The I/O signal line to start the Power Supply is not attached. Press the crimp-on
terminal (terminal block screw, M3) for wiring.
■
The cable to supply power to the Power Supply is not attached. Press the
crimp-on terminal (terminal block screw, M6) for wiring. For the cable to use, see
3. (2) Option
.
■
The cable to connect between the welding transformer and the Power Supply is
not attached. Press the crimp-on terminal (terminal block screw, M6) for wiring.
For the cable to use, see
3. (2) Option
.