MEA-100B
7. Basic Operation
7-3
(3) Welding Schedule and Current Monitor Range Setting
The welding schedule and the current monitor range can be set with the four types
of the control method.
Press the [
] or [
] key to move the cursor to the setting you want to edit. Change
the set value with the [+] or [-] key.
Welding Schedule Setting
Press the [MENU] key to go to the Welding Schedule Setting screen.
Set the schedule for the welding machine being used. The
MEA-100B
can save
31 schedules.
This screen displays different data, according to the welding and control
methods selected.
Current Monitor Range Setting
Press the [MENU] key to go to the Current Monitor Range Setting screen.
Set the current range of the good welding as the monitor upper limit and lower
limit. When the current is out of the range, the error signal is output.
Secondary Constant-Current Control at Multi-Cycle Welding
Welding Schedule Setting
10 0 10 00 0 00 0 10
01 0.95kA 1.00kA 1 1
a
b
c
d
e
f
g
h
i
l
m
j k