MEA-100B
7. Basic Operation
7-5
Power Supply Voltage Fluctuation Compensation Control at Multi-Cycle
Welding
Welding Schedule Setting
Set the welding current (n, o) in a percentage to the maximum current
expressed as 100% (For the maximum current, see 6. (3).)
Item
Setting Range/Display
a–k Same as
Secondary Constant-Current Control at Multi-Cycle
Welding
Welding Schedule Setting
n
Weld Current 1 (CURR.1)
10.0%–99.9%
o
Weld Current 2 (CURR.2)
10.0%–99.9%
Current Monitor Range Setting
Set the upper and lower limits in current value.
Set the limits for W1 and W2 for each schedule.
Item
Setting Range/Display
a
Schedule Number (SCHEDULE NO.) 01–31 schedules
b
Weld 1 upper limit (W1 H)
0.00 (*), 0.01–9.99 kA
c
Weld 1 lower limit (W1 L)
0.00 (*), 0.01–9.99 kA
d
Weld 2 upper limit (W2 H)
0.00 (*), 0.01–9.99 kA
e
Weld 2 lower limit (W2 L)
0.00 (*), 0.01–9.99 kA
(*) When set to 0.00, the current is not monitored.