MEA-100B
11. Timing Chart
11-4
SM on the SET2 screen is set to 2 (For the setting of SM, see 9. (2)
)
Once the start signal is accepted, the welding sequence runs until completion,
even if input of the start signal is stopped.
T1: Time required to start weld force after input of the start signal
SM on the SET2 screen is set to 3 (2-stage start)
(For the setting of SM, see 9. (2)
)
The welding sequence is performed in 2-stage start mode.
The Weld Force signal is output when the 1st stage signal is input. Welding
begins when the 2nd stage signal is input.
The welding sequence runs to completion, even if input of the start signal is
stopped after starting W1.
T1: Time required to start weld force after input of the 1st stage signal
UP2
DWN
SQ
UP1
CO
W2
W1
HLD
T1
OFF
OFF
Welding current
Weld force signal(output)
[SOL1/SOL2]
Start signal(input)
[START(1ST)]
T1
SQ
UP1
CO
UP2
W2
DWN
W1
HLD
OFF
OFF
OFF
2nd stage signal
(input)[2ND STAGE]
1st stage signal
(Start signal)
(input)[START(1ST)]
Welding current
Weld force signal(output)
[SOL1/SOL2]