9. Detail Settings (SET2 Screen)
9-1
9. Detail Settings (SET2 Screen)
Various functions of the
MEA-100B
can be set on the SET2 screen.
The
MEA-100B
is factory-set to a set of standard settings. For most applications, no
editing of these settings is required.
If the settings need to be edited, read this chapter carefully before attempting to do so.
(1) Displaying the SET2 Screen
To display the SET2 screen, press the [MENU] key and the [
] key simultaneously
for at least a second.
There are 8 screens in the SET2 screen (#1 to #8).
Move the cursor to the number on the upper-right part of the screen and press the
[+] or [-] key to select the screen number (#1 to #8).
To return to the MENU screen, press the [MENU] key.
(2) Settings on the SET2 Screen
Screen No.
Settings
#1
Key lock
Control method
Schedule number selection
Start signal input
Start stabilizing time
#2
Stepper-up
Re-weld
Weld skip
End signal output time
Current monitor neglecting cycle
#3
No-current detecting level
No-current neglecting cycle
#4–7
Fault signal attribute setting screen
#8
Communication system
Communication speed
Device number
#1 Screen
Display
Function
Setting
Initial
Setting
a
NP
Disables editing
0: Enables normal key operations
1: Disables setting or editing
0
b
CC
Selects a control
method and welding
current cycle
0: Secondary constant-current control
+ multi-cycle welding
1: Power supply voltage fluctuation
compensation c multi-cycle
welding
2: Power supply voltage fluctuation
compensation c single-
cycle welding
3: Power supply voltage fluctuation
compensation c half-cycle
welding
0
♯1
NP CC SS SM SDT
0
0
0
0
05
a
b
c
d
e