MEA-100B
6. Before the Operation
6-2
(2) Control Method and Welding Current Cycle Settings
Follow the procedure described below and set the control method and welding current
cycle according to the specific application after the
MEA-100B
is installed.
(Secondary constant-current control is factory-set on shipment.)
To display the SET2 screen, press the [MENU] key and the [
] key simultaneously for
at least a second. (For details of the SET2 screen, see
9. Detail Settings
.)
#1
NP
CC
SS
SM
SDT
0
0
0
1
05
Change the value under CC (arrow above) to select a desired control method and
welding current cycle.
Setting
Control Method
Welding Current Cycle
0
Secondary constant-current control
Multi-cycle welding
1
Power supply voltage fluctuation
compensation control
Multi-cycle welding
2
Power supply voltage fluctuation
compensation control
Single-cycle welding
3
Power supply voltage fluctuation
compensation control
Half-cycle welding
After changing, press the [MENU] key to go to the welding schedule setting screen.
(3) Maximum Current Setting
The maximum current is set in one of two ways described below:
A: To set the maximum current of the welding machine directly
To display the SET1 screen, press the [MENU] key and the [
] key simultaneously for
at least a second. When screen is switched to the SET screen, the #1 screen is
always displayed first.
#1
MAX
CURRENT
2.0kA
Move the cursor to and set the maximum current of the welding machine. Setting
range is 0.5 to 9.9 kA.
Caution: When the value is set to lower than 0.5, "
∗∗∗
" will be displayed and
the the maximum current will be set automatically.
For details, see next page.
Caution: Read
9. (2)
carefully before modifying any of the above settings
other than CC.