MEA-100B
13. Specifications
13-5
Item Specifications
Other Functions
Selection of Way to input Start Signal
No self-sustaining function
Self-sustaining from
W1
Self-sustaining
2-stage Start Mode
Selection of Way to change Schedule No.
31-Schedule No. Input without Parity
31-Schedule No. Input with Parity
5-Schedule No. Input
31-Schedule No. Input from Panel
Selection of Start Stabilizing Time
1 ms, 5 ms, 10 ms, 20 ms
ON/OFF of Re-Welding
Selection of End Signal Output Time
10 ms + Start Signal Input Time
10 ms, 200 ms
ON/OFF of Schedule No. Change
Selection of WELD SKIP Signal
Skips to the next sequence. (Skips to
CO
if
W1
is underway.)
Skips to
HLD
.
Trouble
Detection Items
Controller fault
Stepper-up rate error
Start parity error
Count memory error
SCR overheating
⑪
Weld cycle trouble
No current
⑫
Thyristor
shorted
Low welding current
⑬
Self-diagnostics
error
High welding current
⑭
Current setting error
Full wave
⑮
Weld interrupt trouble
Stepper-up end
Operating
Environment
Temperature: 0
–45
C
Humidity:
90% or less (no condensation)
Altitude:
1000 meters or lower
Caution: Use this product in the environment without conductive
dust. If conductive dust enters in the product, this may
result in a failure, electric shock, or fire. When using this
product in this environment, make contact with us.
Storage
Environment
Temperature -10
–55
C and dew condensation not allowed
Heat-Resistant
Class
E
Case Protection
IP20
Power
Consumption
15 W or less in standby
Outline
Dimensions
269 (H) × 142 (W) × 418 (D) mm
Mass
6.5 kg