MEA-100B
14. External Communication Function
14-3
(4) Protocol
Single-directional Communication Mode
1) Monitor Data (sent after each welding)
Data strings:
!01 01 :0,10,1.20,050,20,2.10,110,1,0000,1,0000,00005555 [CR][LF]
A B C D E F G H I J K L M
N
Item
Contents
Character
string
Range
A
Device No.
nn
01 to 31
B
Schedule No.
nn
01 to 31
C
Control Mode
n,
0: Secondary constant-current
c multi-cycle welding
1: Power supply voltage
fluctuation compensation
c multi-cycle welding
2: Power supply voltage
fluctuation compensation
c single-cycle welding
3: Power supply voltage
fluctuation compensation
c half-cycle welding
D
WELD1 Time
nn,
00 to 99 (CYC)
-- for Single-Cycle and Half-Cycle
Control
E
WELD1 Current
n.nn,
0.00 to 9.99 (kA)
F
WELD1 Conduction Angle
nnn,
000 to 180 (
°
)
G
WELD2 Time
nn,
00 to 99 (CYC)
-- for Single-Cycle and Half-Cycle
Control
H
WELD2 Current
n.nn,
0.00 to 9.99 (kA)
-.-- for Half-Cycle Control
I
WELD2 Conduction Angle
nnn,
000 to 180 (
°
)
--- for Half-Cycle Control
J
SOL1 Stepper No.
n,
1 to 5
K
SOL1 Stepper Count
nnnn,
0000 to 9999
L
SOL2 Stepper No.
n,
1 to 5
M
SOL2 Stepper Count
nnnn,
0000 to 9999
N
Total Count
nnnnnnnn 00000000 to 99999999