MEA-100B
10. Interface
10-6
(3) Connection of Input Signals
Connection to Contact Input Device
Use a jumper wire to connect terminals 1 and 2.
Connection to NPN Open Collector Output Device (when using the internal
power supply)
To use the in24 V power supply, connect terminals 1 and 2 with a jumper
wire.
+5V
(Outside)
( I n s i d e )
+
Internal
power
supply
+24V
1
24V-2 EXT
2
24V
Short!
27
COM
28
START(1ST)
+5V
(
Outside)
( I n s i d e )
+
+24V
1
24V-2 EXT
2
24V
Short!
27
COM
28
START(1ST)
Internal