MEA-100B
7. Basic Operation
7-6
Single-Cycle Welding
Welding Schedule Setting
Set the welding current (b, e) in a percentage to the maximum current
expressed as 100% (For the maximum current, see 6. (3).)
Item
Setting Range/Display
a
Squeeze (SQ)
00–99 cycles
b
1st half cycle current (1ST)
10.0%–99.9%
c
Hold (HLD)
00–99 cycles
d
Schedule Number (SCHEDULE NO.) 01–31 schedules
e
2nd half cycle current (2ND)
10.0%–99.9%
f
Weld Force Number (SOLENOID)
1, 2
Current Monitor Range Setting
Set the upper and lower limits in current value.
Set the limits for 1ST and 2ND for each schedule.
Item
Setting Range/Display
a
Schedule Number (SCHEDULE NO.) 01–31 schedules
b
1ST upper limit (1ST H)
0.00 (*), 0.01–9.99 kA
c
1ST lower limit (1ST L)
0.00 (*), 0.01–9.99 kA
d
2ND upper limit (2ND H)
0.00 (*), 0.01–9.99 kA
e
2ND lower limit (2ND L)
0.00 (*), 0.01–9.99 kA
(*) When set to 0.00, the current is not monitored.
Weld Force
Welding Current
SQ
HLD
2ND
1ST
10
1ST
50.0%
10
01
2ND
50.0%
1
a
b
c
d
e
f
1ST H0.00 L0.00kA
01 2ND H0.00 L0.00kA
b
c
a
d
e