![Amada 1000ADP Operation Manual Download Page 89](http://html1.mh-extra.com/html/amada/1000adp/1000adp_operation-manual_2915799089.webp)
APPENDIX D: COMMUNICATIONS
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-922
D-7
SCHEDULE “SS” Set
<ACK
OR
NAK>
1
Byte
SCHEDULE “SR” Read
SCHEDULE # ,
2 Bytes
SQZ #,
(Squeeze Time),
4 Bytes
WS #1,
(Energy in Watt Seconds),
3 Bytes
WS #2,
(Energy in Watt Seconds),
3 Bytes
HOLD #,
(Hold Time),
4 Bytes
PULSE1,
(
weld length
),
1 Byte
PULSE2,
(
weld length
),
1 Byte
POLARITY1,
(
weld polarity
),
1 Byte
POLARITY2,
(
weld polarity
),
1 Byte
UP #,
(Up Slope, 0=Off, 1=On), 1 Byte
21 Bytes Total
-----------------------------------------------------------------------
weld
length
0=Very short, 1=Short, 2=Medium, 3=Long.
weld
polarity
0=Positive, 1=Negative, 2=Alternating.
MONITOR “MS”
Set <ACK
OR
NAK>
1
Byte
MONITOR
“MR”
Read
SCHEDULE
#, 2
Bytes
P1
Upper
Limit,
4
Bytes
P1 Lower Limit,
4 Bytes
P1
Action
(
action
) 1
Byte
P2
Upper
Limit
4
Bytes
P2
Lower
Limit 4
Bytes
19 Bytes Total
-------------------------------------------------------------------------
action
0 = NONE, 1 = INHIBIT P2