![Amada 1000ADP Operation Manual Download Page 57](http://html1.mh-extra.com/html/amada/1000adp/1000adp_operation-manual_2915799057.webp)
CHAPTER 4: OPERATING INSTRUCTIONS
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-922
4-9
Extended Shut-down Procedure
If the ADP unit has been turned off and non-operational for a period of 3 months or longer, an extended
warm-up sequence is recommended.
1.
Turn the unit ON.
2.
Set the energy to the maximum level.
Example:
set the 1000ADP to 999 Watt Seconds.
3.
Fire the unit once.
4.
Leave the power ON and wait 15 minutes.
5.
Program the desired schedule and resume normal operation.