CHAPTER 3. USING DISPLAY SCREENS
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-922
3-3
HOLD TIME
To edit the hold time, press the
SQZ/HOLD
button again.
Press the
SAVE
button to save new values and
return to the original screen.
NOTE:
If you have
not
edited any values,
press the
RUN
button to return to the blue
RUN
screen.
To discard edited values and restore previously
saved values, press the
RUN
key. The system
will respond with the
SAVE
prompt which
appears at the bottom of the screen: "Press
SAVE
to save changes,
CLEAR
to discard." The system
will revert to the original screen.
NOTE:
Whenever the
RUN, MENU
or
LIMITS/COUNTERS
buttons are pressed
before
edited values are saved, the
SAVE
prompt will
appear at the bottom of the screen.