CHAPTER 4: OPERATING INSTRUCTIONS
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
4-6
990-922
8.
Press the or arrows to select
ON
or
OFF
. When this is set to
OFF
, the Power Supply will
not accept RS-232 commands from a remote source to change schedule or control settings.
When this is set to
ON
, the unit will accept these commands. In either case the unit will accept
and respond to RS-232 commands to send out weld data and information.
9.
Press the
MENU
button again to select the
RESET DEFAULTS
field. Use the or arrows to
select ON or OFF. If this value is set to ON and is saved, then all schedules, all weld limits,
Pulse 1 actions,
WELD COUNTER
,
WELD COUNTER LIMIT
and all
MENU
screen entries are set
back to factory defaults.
10.
Press the
SAVE
button to save any changes made. To exit the “editing” mode
without
accepting changes, press RUN to activate the
SAVE
prompt; then press
CLEAR
on the front
panel to discard changes.
Dual Weldhead Operation
For dual weldhead operation, only schedules 1 and 2 are active. To set this feature, connect pin 13 of
the 37 pin Control Signal connector to the I/O common (pin 28 or pin 32). See
Appendix B, Electrical &
Data Connections
for connection details.
1.
Connect weldhead 2 to the 4 pin Standard Air Valve Driver Output Connector.
2.
Connect Weldhead 1 to the 8 pin Weld Head Connector.
3.
Connect the Dual Weldhead Input (pin 13 on the 37 pin connector) to the I/O common (pin 28
or 32 on the 37 pin connector).
4.
Schedule 1 will then use weldhead 1 and schedule 2 will use weldhead 2. These two heads and
schedules will fire alternately with the Footswitch input. Do not use the RS-232 commands or
the Binary Schedule Select inputs to change weld schedules when Dual Weldhead operation is
active.
Programming Lock
The programmed values of the 63 schedules can be locked so that no changes are possible. To set this
lock, connect pin 9 of the 37 pin Control Signal connector to the I/O common (pin 28 or pin 32). See
Appendix B, Electrical & Data Connections
for connection details.
NOTE:
The schedule numbers can still be changed, but the values stored in each schedule can
not
be
changed.
Schedule Lock
The programmed values of the 63 schedules and the schedule number itself can be locked so that no
changes are possible. To set this lock, connect pin 27 of the 37 pin connector to the I/O common
(pin 28 or pin 32). See
Appendix B, Electrical & Data Connections
for connection details.
Summary of Contents for 1000ADP
Page 1: ...990 922 Rev G STORED ENERGY POWER SUPPLY 125 300 1000ADP OPERATION MANUAL...
Page 8: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY viii 990 922...
Page 9: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY 990 922 ix...
Page 14: ......
Page 24: ......
Page 58: ......
Page 64: ......
Page 82: ......
Page 92: ......