CHAPTER 2: INSTALLATION AND SETUP
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-922
2-5
Weld Head Connections to Power Supply Terminals
1.
Turn the AC power turned OFF.
2.
Connect one end of a weld cable to the negative (
-
) welding transformer terminal on the Power
Supply (or external transformer for a 1000ADP).
3.
Connect one end of the second weld cable to the positive (
+
) welding transformer terminal on
the Power Supply (or external transformer for a 1000ADP).
4.
Connect the other end of the weld cables to the weld head.
5.
Install electrodes in the weld head electrode holders.
NOTE:
If you need additional information about the weld heads, please refer to the
manufacturer's user manuals.