C613-50170-01 Rev B
Command Reference for x510 Series
319
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
P
LUGGABLES
AND
C
ABLING
C
OMMANDS
SHOW
SYSTEM
PLUGGABLE
DIAGNOSTICS
Output
Figure 8-5:
Example output from the
show system pluggable diagnostics
command on a device
Related
Commands
awplus#show system pluggable diagnostics
System Pluggable Information Diagnostics
Port1.0.25 Status Alarms Warnings
Reading Alarm Max Min Warning Max Min
Temp: (Degrees C) 29.387 - 100.00 -40.00 - 85.000 -10.00
Vcc: (Volts) 3.339 - 3.465 3.135 - 3.400 3.200
Tx Bias: (mA) 10.192 - 37.020 3.260 - 34.520 5.760
Tx Power: (mW) 17.872 - 35.643 8.953 - 28.313 11.271
Rx Power: (mW) 0.006 Low 15.849 0.025 Low 12.589 0.040
Rx LOS: Rx Down
Port1.0.26 Status Alarms Warnings
Reading Alarm Max Min Warning Max Min
Temp: (Degrees C) 29.387 - 100.00 -40.00 - 85.000 -10.00
Vcc: (Volts) 3.378 - 3.630 2.970 - 3.465 3.135
Tx Bias: (mA) 2.802 - 6.000 1.000 - 5.000 1.000
Tx Power: (mW) 2.900 - 11.000 0.600 - 10.000 0.850
Rx Power: (mW) 1.739 - 18.000 0.000 - 10.000 0.200
Rx LOS: Rx Up
Table 9:
Parameters in the output from the
show system pluggables
diagnostics
command
Parameter
Description
Temp (Degrees C)
Shows the temperature inside the transceiver.
Vcc (Volts)
Shows voltage supplied to the transceiver.
Tx Bias (mA)
Shows current to the Laser Diode in the transceiver.
Tx Power (mW)
Shows the amount of light transmitted from the transceiver.
Rx Power (mW)
Shows the amount of light received in the transceiver.
Rx LOS
Rx Loss of Signal. This indicates whether:
•
light is being received (Rx Up) and therefore the link is up,
or
•
light is not being received (Rx Down) and therefore the
link is down